HV-LI-PROBE
HV-LI-PROBE
HV-LI-PROBE | ||||
Resistance [mΩ] | Max. continous current [A] | Cable Cross size [mm2] | Measuring range [A] | Resolution [mA/Bit] |
1,000 | 1.05 | 1.5 | -0.24 / +1,05 | 0.3 |
500 | 2.1 | 1.5 | -0.48 / +2,1 | 0.6 |
100 | 6.5 | 1.5 | -2.4 / +10,5 | 3 |
50 | 9.5 | 1.5 | -4.8 / +21 | 6 |
25 | 12 | 1.5 | -9.6 / +42 | 12 |
10 | 21 | 4 | -24 / +105 | 30 |
5 | 25 | 4 | -48 / +210 | 60 |
2 | 40 | 4 | -120 / +525 | 150 |
1 | 58 | 6 | -240/+1,050 | 300 |
Indication in each case in the smallest measuring range
valid for our MULTI-HV measurement modules
Please note that the permitted continuous current may be smaller than the measuring range.
HV-LI-PROBE for shunt-based measurement of quiescent, operating, and peak currents in high-voltage electrical systems in vehicles or test benches. Potted measurement resistor with cable outlets and open cable ends for integration into the measurement circuit. Automatic probe identification.
Features
Version
Construction
Application
Scope of Delivery
Accessories
Code for Order
Name |
Shunt Value |
L1 |
L2 |
L3 |
---|---|---|---|---|
LI | 1000/ … /1 | 1 | 1…5 | 0 |