HV Power Sensors
HV-HP-PROBE
HV-HP-PROBE for measuring voltages and currents from µA to kA
Probe-Variations

HV-HP-Probe

BF1+: Dimensons 53.6/17.5/15 mm (L/W/H) – M5 holes
BF2: Dimensons 68/20/20 mm (L/W/H) – M8 holes
BF2+: Dimensons 84/20/20 (mm L/W/H) – M8 holes
BF3: Dimensons 84/57/20.5 mm (L/W/H) – M8 holes

Datasheet
Request

HV-HP-PROBE

Specification in each case in the smallest measuring range at room temperature (23°C)

HV-HP-PROBE for shunt-based measurement of quiescent, operating, and peak currents as well as voltages in high-voltage electrical systems in vehicles or test benches. The measurement shunt resistor is installed directly into the circuit via mounting tabs. Types BF1 to BF3. Automatic probe identification.

Features

The HV-HP Probe consists of both a voltage and a current probe.

  • Current measurement:
    • The measuring resistor is installed directly in the circuit via mounting lugs.
    • The measuring circuit has to be fused by the customer.
  • Voltage measurement:
    • The measurement is performed with the use of a voltage divider, which reduces the input voltage to a value permissible for the modules.
  • The measuring resistor is installed directly in the circuit via mounting lugs (BF1 - M6, BF2 & BF3 - M8)
  • For applications up to 2,200 A continuous current (depending on type)
  • High precision shunt based current measurement for quiescent and operating currents
  • Automatic Probe Detection (TEDS similar)

Version

Type: BF1+, BF2, BF2+, BF3

Construction

  • Measuring resistor with mounting lugs (temperature range -40...+130°C) and voltage divider
  • Memory chip for sensor identification and calibration data (TEDS similar)
  • U-probe, measuring cable voltage = L3 (0.5m), heat-resistant and highly flexible with free cable end
  • Data cable = L2 (1/3/5 m) with 8-pin Redel connector

Application

  • Power measurement of power electronics in the vehicle or on test benches
  • Voltage measurements in the HV on-board network
  • HV batteries

Scope of Delivery

  • HV-HP-PROBE
  • Factory calibration certificate(DAkkS optional)

Accessories

  • HV-Probe extension cable

Code for Order

BF1+

Name Resistance Value L1 L2 L3
HV-HP-BF1+ 2/…/0,2 0 1…5 0

BF2

Name Resistance Value L1 L2 L3
HV-HP-BF2 2/…/0,1 0 1…5 0

BF2+

Name Resistance Value L1 L2 L3
HV-HP-BF2+ 2/…/0,035 0 1…5 0

BF3

Name Resistance Value L1 L2 L3
HV-HP-BF3 0,02/…/0,005 0 1…5 0
list_weiss
mail_weiss
phone_weiss