Current measurement
FUSE-Probe (Micro/ Mini/ ATO/ MAXI/ MCASE/ JCASE)
HI-Probe (BF1/ BF2/ BF3)
LI-Probe
Voltage measurement
U-Probe (80V)
Power measurement
HP-Probe (Option)
LP-Probe (Option)
Temperature measurement
T-Probe (Pt100/ Pt1000)
Measurement range of the inputs
| Gain | Measuring range [mV] | Resolution [µV/Bit] |
| 100 | ± 9 | 0,3 |
| 40 | ± 27 | 0,9 |
| 25 | ± 42 | 1,4 |
| 5 | ± 210 | 7 |
| 1 | + 1.050/-240 | 35 |
Measurement range HI-Probe
| HI-PROBE | ||||
| 1 mΩ | 200 μΩ | |||
| Gain | Measuring range [A] | Resolution [mA/Bit] | Measuring range [A] | Resolution [mA/Bit] |
| 100 | ± 9 | 0,3 | ± 45 | 1,5 |
| 40 | ± 27 | 0,9 | ± 135 | 4,5 |
| 25 | ± 42 | 1,4 | ± 210 | 7 |
| 5 | ± 210 | 7 | ± 1.050 | 35 |
| 1 | + 1.050/-240 | 35 | + 5.250/-1.200 | 175 |
Measurement range U-Probe
| 80 V | ||
| Gain | Measuring range [V] | Resolution [mV/Bit] |
| 100 | +/- 6 | 0.2 |
| 40 | +/- 18 | 0.6 |
| 25 | +/- 28 | 0.9 |
| 5 | +/- 80 | 5 |
Compact and robust CAN measurement module for low voltage applications. Housing mechanically stackable with devices for fixing in measuring environment.
Features
Version
Accesories
Applications
Scope of delivery
Technical data
| Inputs | 4 Measurement inputs (8 channels) |
| Capabilities | Klaric Probes with automatic recognition and acceptance of calibration values Current Voltage 2xVoltage (Option) Power (Option) PT100/1000 |
| Resolution | 16 bit ADC with 5 measuring ranges |
| Sample Rate | 0,25 Hz bis 8 kHz configurable per channel |
| Measurement Ranges | ±9 mV, ±27 mV, ±42 mV, ±210 mV, +1050 / -240 mV 0,4 µV, 0,9 µV, 1,4 µV, 7 µV, 35 µV resolution |
| Accuracy | ± 0,1 % reading ± 3 Bit of the actual measurement range at 23 °C ± 5 °C ± 1 % reading ± 3 Bit of the actual measurement range -40 °C bis +80 °C |
| CAN Interface | 125k, 250k, 500k, 1000k Baud configurable Internal CAN termination can be activated via software CAN base ID configurable |
| Configuration via | CAN |
| Voltage Supply Range | 7 V – 60 V |
| Power Consumption | typ. 1,5 W |
| Temperature Range | -40 °C to +85 °C |
| Calibration | Every 12 months (recommended) |