Measurement Range BF2
Resistance | Measuring range | Resolution/ Bit* | Max. permanent current** |
2 mΩ | -120 bis +525 A | 0,150 mA | 80 A |
1 mΩ | -240 bis +1.050 A | 0,3 mA | 120 A |
0,5 mΩ | -480 bis +2.100 A | 0,6 mA | 130 A |
0,2 mΩ | -1.200 bis +5.250 A | 1,5 mA | 180 A |
0,1 mΩ | -2.400 bis +10.500 A | 3 mA | 310 A |
0,05 mΩ | -4.800 bis +21.000 A | 6 mA | 400 A |
0,035 mΩ | -6.850 bis +30.000 A | 8,6 mA | 480 A |
Measurement Range BF3
Resistance | Measuring range | Resolution/ Bit* | Max. permanent current** |
0,02 mΩ | -6.000 bis +8000 A | 15 mA | 400 A |
0,005 mΩ | -8.000 bis +8.000 A | 60 mA | 650 A |
HV BREAKOUT-BOX HIGH POWER with original plugs were developed for safe and precise measurements on batteries and power electronics in high-voltage environments.
The integrated original sockets and original plugs are perfectly integrated into the robust aluminum housing and can be used either as a replacement or as an extension for the original wiring harness. The high-power variant aims to measure the current and voltage of the battery output and battery input between the power distribution unit (PDU) and the inverter.
Features
Fabrication
Accessories
Application
Scope of delivery