HP-Probes
BF1: Dimensons 41.6/17.5/15 mm (L/W/H) – M5 holes
BF1+: Dimensons 53.6/17.5/15 mm (L/W/H) – M5 holes
BF2: Dimensons 68/27.5/14.5 mm (L/W/H) – M8 holes
BF2+: Dimensons 84/27.5/14.5 (mm L/W/H) – M8 holes
BF3: Dimensons 84/57/20.5 mm (L/W/H) – M8 holes
HP-PROBE
U-PROBE | ||||
80 V | ||||
Gain | Measuring range [V] | |||
100 | ± 6 | 0.2 | ||
40 | ± 18 | 0.6 | ||
25 | ± 28 | 0.9 | ||
5 | ± 80 | 5 |
BF1/1+ | |||
Resistance [mΩ] | Measuring range [A] | Resolution [mA/Bit] | Max. permanent current [A] |
2 | -120 / +525 | 0.150 | 60 |
1 | -240 / +1,050 | 0.3 | 80 |
0.5 | -480 / +2,100 | 0.6 | 120 |
0.2 | -1,200 / +5,250 | 1.5 | 150 |
Specification in each case in the smallest measuring range at room temperature (23°C)
BF2 | |||
Resistance [mΩ] | Measuring range [A] | Resolution [mA/Bit] | Max. permanent current [A] |
2 | -120 / +525 | 0.15 | 80 |
1 | -240 / +1,050 | 0.3 | 120 |
0.5 | -480 / +2,100 | 0.6 | 130 |
0.2 | -1,200 / +5,250 | 1.5 | 180 |
0.1 | -2,400 / +10,500 | 3 | 310 |
Specification in each case in the smallest measuring range at room temperature (23°C)
BF2+ | |||
Resistance [mΩ] | Measuring range [A] | Resolution [mA/Bit] | Max. permanent current [A] |
2 | -120 / +525 | 0.15 | 80 |
1 | -240 / +1.050 | 0.3 | 120 |
0.5 | -480 / +2,100 | 0.6 | 130 |
0.2 | -1,200 / +5,250 | 1.5 | 180 |
0.1 | -2,400 / +10,500 | 3 | 310 |
0.05 | -4,800 / +21,000 | 6 | 500 |
0.035 | -6,850 / +30,000 | 9 | 650 |
Specification in each case in the smallest measuring range at room temperature (23°C)
BF3 | |||
Resistance [mΩ] | Measurement range [A] | Resolution [mA/Bit] | Continuous current [A] |
0.020 | -12,000 / +52,500 | 15 | 1,000 |
0.005 | -48,000 / 210,000 | 60 | 2,200 |
Specification in each case in the smallest measuring range at room temperature (23°C)
HP-PROBE for shunt-based measurement of quiescent, operating, and peak currents as well as voltages in low-voltage onboard electrical systems in vehicles or test benches. The measurement shunt resistor is installed directly into the circuit via mounting tabs. Resistance values ranging from µΩ to mΩ. Types BF1 to BF3. Automatic probe identification.
Features
The HP-PROBES consist of both a voltage and a current Probe.
Version
Construction
Applications
Scope of Delivery
Accessories
Code of Order
BF1
Name |
Shunt Value |
L1 |
L2 |
L3 |
---|---|---|---|---|
HP-BF1 | 2/…/0,5 | 0 | 1…5 | 0 |
BF1+
Name |
Shunt Value |
L1 |
L2 |
L3 |
---|---|---|---|---|
HP-BF1+ | 2/…/0,5 | 0 | 1…5 | 0 |
BF2
Name |
Shunt Value |
L1 |
L2 |
L3 |
---|---|---|---|---|
HP-BF2 | 2/…/0,035 | 0 | 1…5 | 0 |
BF2+
Name |
Shunt Value |
L1 |
L2 |
L3 |
---|---|---|---|---|
HP-BF2+ | 2/…/0,035 | 0 | 1…5 | 0 |
BF3
Name |
Shunt Value |
L1 |
L2 |
L3 |
---|---|---|---|---|
HP-BF3 | 0,05/…/0,025 | 0 | 1…5 | 0 |