Charging standard variants
AC
Mennekes Type 1/2, GB/T AC
CEE 32/63 oder 125
DC
CCS Type 1
CCS Type 2
GB/T DC
CHAdeMO
EV CHARGE-MONITOR RUGGED for measurement between the building connection and the charging station or between the charging station and the electric vehicle.
Output of data on display, storage of measurement data via USB memory as well as output via CAN interface.
Customizable interfaces for charging stations.
Features
Version
Applications
Scope of Delivery
Technical Data
Connectivity | AC Mennekes Type 1/2, GB/T AC,CEE 32/63 or 125 DC CCS Type 1, CCS Type 2,GB/T DC, CHAdeMO |
Resolution | 16 Bit ADC with 5 measuring ranges |
Sampling rate | 0.25 Hz to 8 kHz per channel configurable, dynamically triggerable via threshold |
Measuring ranges | ±9 mV, ±27 mV, ±42 mV, ±210 mV, +1050 / -240 mV 0.4 µV, 0.9 µV, 1.4 µV, 7 µV, 35 µV resolution |
Measurement accuracy | ± 0.1% of the measured value ± 3 bits per measuring range at 23°C ± 5°C ± 1% of the measured value ± 3 bits per measuring range -40°C to +80°C Measuring module + Klari - Probe |
CAN interface | 125k, 250k, 500k, 1000k baud configurable internal CAN termination can be activated via software CAN base ID configurable |
Configuration via | USB (virtual COM Port) CAN Ethernet 10" Touch Display |
Voltage supply | 120/ 230 VAC 12/24V DC |
Current consumption | typ. 12 W |
Temperature range | -20°C to +65°C |
Calibration | Factory calibration or DAkkS calibration Recommended every 12 months |
HV insulation check | at least every 12 months |