C
Compact electronic load for testing and conditioning batteries (12V/ 24V) with the functions: Charge, discharge and cycle (charge/discharge).
Probe-Variations
Request

The measured values of current, voltage and charge/discharge balance can be sent via a CAN interface and/or stored on an integrated SD card.

Modi

Charge
The charging process takes place via an external charger

Configuration:

Charging current: min./max.value
Charging voltage: min./max. value
Ah charging: selectable
Charging time selectable

Discharge:
The battery is discharged by the integrated ELAST unit

Configuration:

Discharge mode: Static (constant current) or PWM (pulse width modulation) load.
External charging: On/Off
U-charge: selectable (when the threshold is exceeded, the discharge is stopped)
Static ( I - constant current between 10mA...50A )
I-Constant: discharge current, selectable
Discharge time: selectable
Ah balance: selectable

PWM load (I - pulse, pulse width modulation)

I-load 1 : Discharge current, selectable
I-load 2: Discharge current, selectable
Time On: Time period of I-load1, selectable Time Period - Time On(I-load 1)
Time-Period: Duration of one period, selectable = Time-On(I-load 2).
Time: time period for the whole measurement, selectable.
The following values are monitored during the discharge process:
I_Batt min./max. in case of exceeding/falling below, the shutdown.

U_Batt min. when falling below, switch-off
U_Batt max. must correspond to the battery used
The discharging process is terminated when:
U_Batt min reached, - Ah value reached,
U_charge value reached, - I_Batt min reached.

Cycle

Charge/discharge cycles are run down

Configuration:

n-charge : selectable
n-discharge : selectable

 

Version

Aluminum housing, 465/390/245 mm (L/W/H)
Protection class IP54,
temperature range -20...+50°C
Power supply 230 V AC, current consumption approx. 2 A

For detailed technical information please refer to the user manual

Scope of Delivery
Measuring unit
Battery connection cable with DINSE pole plugs
2 DINSE pole plugs with copper pins, Ø 6 mm for connecting the charger
PC software for configuration via CAN or USB 2.0 interface
CAN database and documentation on CD ROM
USB 2.0 connection cable
With the Klari-Viewer software the recorded measured values can be displayed and further processed.

Accessories
Battery connection cable with DINSE pole plugs
2 DINSE pole plugs with Cu pins, Ø 6 mm

list_weiss